Opto-Link Corporationについて
2000年に設立された光ファイバ装置・光ファイバ部品のメーカー(旧社名:Opto-Link)。
ASE,SLED光源(ベンチトップ/モジュール型),EDFA増幅器,Er添加ファイバ増幅器(ベンチトップ/モジュール型),光ファイバ部品等に
特化してカスタム化にも対応し、通信・研究開発・光学センサー用途等で幅広く用いられています。
製品 – products
Fiber Optics Equipments | |
---|---|
製品名 | 製品名 |
ASE Benchtop / modules | SLED sources |
EDFA Benchtop / modules | SWB sources |
Pump laser light sources | Variable Optical attenuators (VOA) |
光ファイバー装置(Fiber Optic Equipment)
ASE Light source
Opto-Link provides Amplified Spontaneous Emission Light sources in C-L bands and around 1050nm, in OEM or standalone packages.
Applications:
- Spectral measurements of C-Band DWDM passive components
- Noise simulation in DWDM systems
- Fiber optics sensors PMD measurement
C-band standalone source (PDF):
Parameter | Performance | |
Wavelength | 1525 nm ~ 1565 nm | |
Total Output Power | >+10 dBm (+20 dBm, Maximum) | |
Spectrum Density | > -4 dBm/nm (15 dBm typical 1528 nm to 1563 nm) | |
Spectrum Flatness |
< 1 dB at low output power (3~8 dBm) | |
< 2 dB at high output power (< 17 dBm) | ||
Output Stability | ± 0.02 dB (8 hrs) | |
Output Connector | FC/APC, others on request | |
Operating Temperature |
0°C to 40 °C
|
|
Storage Temperature |
-40°C to 70 °C
|
|
Dimensions |
230.5 mm x 89 mm x 300 mm
|
|
Power Supply |
230/110 V 50/60 Hz
|
|
Displays |
Optical Output Power
|
|
Controls |
Keylock switch, Output Optical Power
|
|
Alarms |
Laser Indicator and Alarm Indicator
|
|
Computer Interface |
RS-232 (optional)
|
C-band OEM module (PDF):
Parameter | Performance |
Wavelength | 1525 nm ~ 1565 nm |
Spectrum Density | > -4 dBm/nm (15 dBm typical 1528 nm to 1563 nm) |
Spectrum Flatness |
< 2 dB (Pout <17dBm, with GFF), ± 3dB (without GFF) |
Total Output Power |
> +10 dBm (+17 dBm, Maximum) |
Output Stability | ± 0.02 dB (8 hrs) |
Operating Humidity | 5% to 95% |
Operating Temperature | 0 °C to +50 °C |
Storage Temperature | -40 °C to +70 °C |
Voltage | +5V DC |
Output Connector | FC/APC, others on request |
Dimensions | 150mm x 125mm x 24mm |
C+L band standalone source (PDF):
Parameter | Performance | ||
Spectral Range |
1525 nm ~ 1610 nm
|
||
Total Output Power |
> +10 dBm ( +15 dBm, Maximum)
|
||
Spectrum Flatness |
< 3 dB (1528 nm to 1600 nm at 20°C ~ 30°C)
|
||
Output Stability |
±0.02 dB (8 hrs)
|
||
Output Isolation |
> 30 dB
|
||
Output Connector |
FC/APC or others on request
|
||
Operating Temperature |
0 °C to 40 °C
|
||
Storage Temperature |
-40 °C to 70 °C
|
||
Dimensions |
230.5 mm x 89 mm x 300 mm
|
||
Power Supply |
230/110 V 50/60 Hz
|
||
Displays |
Optical Output Power
|
||
Controls |
Keylock Switch, Output Optical Power
|
||
Alarms |
Laser Indicator and Alarm Indicator
|
||
Computer Interface |
RS-232 (optional)
|
C+L OEM module:
Parameter | Performance |
Wavelength | 1525 nm ~ 1610 nm |
Spectrum Density | > -10 dBm/nm |
Spectrum Flatness |
< 3.5 dB (1530 nm to 1600 nm at 23°C with GFF)
|
Total Output Power |
> +10 dBm (+19 dBm, Maximum) |
Output Stability | ± 0.02 dB (8hrs) |
Operating Humidity | 5% to 95% |
Operating Temperature | 0 °C to +50 °C |
Storage Temperature | -40 °C to +70 °C |
Voltage | +5V DC |
Output Connector | FC/APC, others on request |
Dimensions | 150mm x 125mm x 24mm |
ASE 1050nm source (PDF):
Applications:
- Fiber Optic Sensing
- Optical Tomography
- Component Characterization
- High Power Fiber Laser
Parameter |
Values
|
Units
|
|
Total Output Power |
> +10
|
> +13
|
dBm
|
Wavelength |
1040 to 1075
|
1020 to 1080
|
nm
|
Spectrum Density |
> -12
|
dBm/nm
|
|
Output Stability |
+/-0.02 (8 hrs)
|
dB
|
|
Optical Connector
|
FC/APC, others on request
|
—
|
1050nm Polarization-Maintaining ASE light source:
Wavelength | Output Power |
1022~1078 nm | 10 dBm |
1040~1085 nm | 27 dBm |
Order Code: see PDF.
Other configurations on request.
EDFA
Opto-Link provides Erbium-doped Fiber Amplifiers in different packages.
Applications:
- Optical Networks
- Lab Applications
- Testing
Benchtop (PDF)
C-band Benchtop
Parameter | Min | Typ | Max | Unit | |
Operating Wavelength | 1530 | 1550 | 1560 | nm | |
Input Power * | Booster | -6 | +3 | dBm | |
In-Line Amplifier | -25 | -3 | |||
Pre-Amplifier | -40 | -10 | |||
Output Power ** | Booster | +15 | dBm | ||
In-Line Amplifier | +15 | ||||
Pre-Amplifier | -10 | +10 | |||
Noise Figure (@-20dBm Input Power) | 5.5 | dB | |||
Isolation | Input | 30 | dB | ||
Output | 30 | dB | |||
Polarization Dependent Gain (PDG) | 0.3 | 0.5 | dB | ||
Polarization Mode Dispersion (PMD) | 0.3 | 0.5 | ps | ||
Operating Temperature | 0 | 40 | ºC | ||
Storage Temperature | -10 | 70 | ºC | ||
Voltage | 220/110 | V | |||
Interface | RS232 | ||||
Dimensions |
Bench top: 300 * 250 * 100 Rack Mount: 201 * 482.6 * 43.6 |
mm |
C+L band single channel benchtop (booster):
Parameter | Min | Typ | Max | Unit | |
Operating Wavelength | C-Band | 1528 | 1562 | nm | |
L-Band | 1570 | 1603 | nm | ||
Input Power * | -6 | 3 | dBm | ||
Output Power (@ 0dBm Input Power) ** | 15 | dBm | |||
Noise Figure (@ 0dBm Input Power) | 5.5 | dB | |||
Isolation | Input | 30 | dB | ||
Output | 30 | dB | |||
Return Loss | Input | 45 | dB | ||
Output | 45 | dB | |||
Operating Temperature | 0 | 40 | ºC | ||
Storage Temperature | -10 | 75 | ºC | ||
Voltage | 220/110 | V | |||
Interface | RS232 | ||||
Dimensions | Bench top: 300 * 250 * 100Rack Mount: 201 * 482.6 * 43.6 | mm |
* Other input power range available.
** Other output power available.
High-Power 27dBm C-band benchtop (PDF)
Parameter | Specifications | Units | ||
Output Power (Input Power = -3dBm) | Min. 27 | Min. 30 | Min.33 | dBm |
Input Power | -6 to +3 | dBm | ||
Noise Figure (Input Power = 0dBm) | 5.5 | 6 | 6.5 | dB |
Operating Wavelength | 1540~1565 | nm | ||
Input/Output Isolation | > 30 | dB | ||
Polarization Dependent Gain | < 0.3 | dB | ||
Operation Temperature Range | 0 to +40 | ºC | ||
Storage Temperature Range | -10 to +70 | ºC | ||
Power Supply | 80~240, 43~63Hz | V AC | ||
Dimensions | 350 x 300 x 100 for Benchtop | |||
482 x 350 x 42 for 19″ Rackmount | mm | |||
Control | Keylock switch, Optical Output Power | — | ||
LCD Display | Optical Output Power, Pump Laser Temperature | — | ||
Interface | RS232 | — | ||
Protection | Pump Laser Overheat Warning | — | ||
Optical output connector | FC/APC, FC/UPC, SC/APC, SC/UPC | — | ||
Fiber Type | SMF-28 | — |
High-Power 33dBm C-band benchtop (PDF)
Parameter | Specifications | Unit |
Operating Wavelength | 1540 ~ 1565 | nm |
Saturated Output Power | 33 at Pin = -3dBm | dBm |
Optical Input Power | -15 to +5 | dBm |
Noise Figure | <6.5 | dB |
Small Signal Gain | >40 | dB |
Gain Variation | <1.5 at Pin = -3dBm | dB |
Polarization Dependent Gain | <0.5 | dB |
Polarization Mode Dispersion | <1 | ps |
Optical Isolation | >30 | dB |
Return Loss | <-40 | dB |
AC Voltage | 85 – 264 (47 to 63Hz) | V |
Power Consumptiopn | 30 ~ 100 (Depending on Output Power) | W |
Operating Case Temperature | +5 to +55 | ºC |
Storage Temperature | -40 to +75 | ºC |
Size | 160 x 260 x 380 (Bench-Top) | |
88 x 427 x 446 (Rack Mount) | mm | |
Fiber Type | SMF-28 | — |
Standard Connector | FC/APC | — |
Inteface | GPIB, RS232 | — |
Control | ACC, APC | — |
Order Code: see PDF.
Other configurations on request.
Metro EDFA (PDF)
Mini-sized EDFA module for applications:
- Access Network
- Metro-Fiber Optic Transmission System
Parameter |
Performance
|
Unit
|
|
Operating Wavelength | 1530~1565 |
nm
|
|
Input Power | -10 to +4 |
dBm
|
|
Output Power | +10 |
dBm
|
|
Noise Figure | < 6 (@1550nm, 0dBm Input, 10dBm Output) |
dB
|
|
Reverse ASE Leakage | < -20 |
dBm
|
|
Output Pump Leakage | < -30 |
dBm
|
|
Return Loss | Input | > 40 |
dB
|
Output | > 40 |
dB
|
|
PMD | < 1.0 |
ps
|
|
PDG | < 0.5 |
dB
|
|
Power Dissipation | < 2 |
W
|
|
Operating Temperature | -5 to 65 |
ºC |
|
Storage Temperature | -40 to +85 |
ºC
|
|
Dimensions | 90 x 70 x 15 |
mm
|
Order Code: see PDF.
Other configurations on request.
EDFA for DWDM (PDF)
Applications:
- Digital communication networks
- DWDM systems
Parameter | Performance | Unit | ||
Operating Wavelength | 16 Channels | 1546~1561 | nm | |
32 Channels | 1535~1562 | nm | ||
40 Channels | 1527~1562 | nm | ||
Input Power | Booster Amplifier | -14 to +5 | dBm | |
In-Line Amplifier | -26 to 0 | dBm | ||
Pre-Amplifier | -29 to -5 | dBm | ||
Output Power | Max | 21 | dBm | |
Gain | 14 to 33 | dB | ||
Noise Figure | Booster Amplifier | 5.0 | dB | |
In-Line Amplifier | 5.0 | dB | ||
Pre-Amplifier | 4.5 | dB | ||
Gain Flatness | 1.0 | dB | ||
Isolation | Input | Min | 30 | dB |
Output | Min | 30 | dB | |
Output Pump Leakage | Max | -30 | dBm | |
Return Loss | Input | Min | 45 | dB |
Output | Min | 45 | dB | |
Polarization Mode Dispersion | Max | 0.5 | ps | |
Polarization Dependent Gain | Max | 0.5 | dB | |
Power Consumption | Max | 30 | W | |
Operating Temperature | 0 to 65 | ºC | ||
Operating Humidity | 5 to 95 | % | ||
Storage Temperature | -40 to 85 | ºC | ||
Dimension | Electric Module: (W x L x H) 150x125x24
Optical Module: (W x L x H) 120x100x25 |
mm |
Order Code: see PDF.
Other configurations on request.
EDFA for SDH (PDF)
Applications:
- Synchronous Digital Hierarchy (SDH) networks
Parameter | Performance | Unit | ||
Operating Wavelength | 1530 to 1565 (Typical: 1550) | nm | ||
Input Power | Booster Amplifier | -6 to +4 | dBm | |
In-line Amplifier | -34 to -6 | dBm | ||
Pre-Amplifier | -45 to -25 | dBm | ||
Output Power | Booster Amplifier | 10 to 19 | dBm | |
In-line Amplifier | 0 to 19 | dBm | ||
Pre-Amplifier | Max | -9 | dBm | |
Noise Figure | Booster Amplifier | Typ | 5.0 | dB |
In-line Amplifier | Typ | 4.5 | dB | |
Pre-Amplifier | Typ | 4.5 | dB | |
Isolation | Input | Min | 30 | dB |
Output | Min | 30 | dB | |
Output Pump Leakage | Max | -30 | dBm | |
Return Loss | Input | Min | 45 | dB |
Output | Min | 45 | dB | |
Polarization Dependent Gain (PDG) | Max | 0.5 | dB | |
Power Consumption | Max | 25 | W | |
Operating Temperature | 0 to 50 | ºC | ||
Operating Humidity | 5 to 95 | % | ||
Storage Temperature | -40 to 75 | ºC | ||
Voltage |
RackMount:-48DC
Module Type:+5DC |
V | ||
Dimensions |
Rack Mount: (W x H x L) 482.6x201x43.6 Module Type: (W x H x L) 150x125x24 |
mm |
Order Code: see PDF.
Other configurations on request.
Multifunctional EDFA (PDF)
Applications:
- Digital communication networks
- DWDM systems
Parameter | Performance | Unit | |
Operating Wavelength | 1527~1562 | nm | |
Total Input Power | -30 to -9 (Typ:-12) | dBm | |
Total Output Power | 5 to 20.5 (Typ:20) | dBm | |
Gain | 29 to 35 (Typ:32) | dB | |
First Stage Gain | 24 to 30 ( Typ:27) | dB | |
Second Stage Gain | Typ | 15 | dB |
Noise Figure | Max | 6.0 (Typ:5.5) | dB |
Gain Flatness | Max | 1.0 | dB |
Middle Stage Insertion Loss | Typ | 10 | dB |
Isolation (Input/Output) | Min | 30 | dB |
Output Pump Leakage | Max | -30 | dBm |
Return Loss (Input/Output) | Min | 40 | dB |
Polarization Mode Dispersion (PMD) | Max | 0.5 | ps |
Polarization Dependent Gain (PDG) | Max | 0.5 | dB |
Operating Temperature | 0 to 65 | ºC | |
Operating Humidity | 5 to 95 | % | |
Storage Temperature | -40 to 85 | ºC | |
Power Consumption | Rack Mount:50 | W | |
Module Type:30 | |||
Dimension | Rack Mount: (W x H x L) 437x239x43.6 | mm | |
Module Type: (W x H x L) 150x125x23 |
Order Code: see PDF.
Other configurations on request.
Pump laser Light source (PDF)
Opto-Link provides Pump laser sources at 980 and 1480nm with powers from 100 to 300mW.
Applications:
- Fiber amplifiers
- Fiber optic sensors
- EDFA applications
- CATV
* The specification for the Pump Laser device without connector.
* Isolator only applied to 1480nm Pump Laser.
980nm Pump Laser | |
OLPL-98-10 | 100mW |
OLPL-98-15 | 150mW |
OLPL-98-20 | 200mW |
OLPL-98-25 | 250mW |
OLPL-98-30 | 300mW |
1480nm Pump Laser | |
OLPL-48-10 | 100mW |
OLPL-48-15 | 150mW |
OLPL-48-20 | 200mW |
OLPL-48-25 | 250mW |
OLPL-48-30 | 300mW |
Order Code: see PDF.
Other configurations on request.
SLED Light source
Opto-Link provides Superluminescent LED from 680 to 1600nm.
Applications:
- Fiber Amplifiers
- Fiber Optic Sensors
- Components Testing
- Instrumentation
- Fiber Optic Gyroscope
- Fiber Optic Communications
- Optical Coherence Tomography (OCT)
- Biomedical Imaging Device
680nm (PDF):
Wavelength (nm) | Model | Central Wavelength (nm) | Spectrum Width (nm) | Power (mW) |
680 | OLSLD-68-MP | 680 | 8.5 | 1 |
OLSLD-68-HP1 | 680 | 8 | 5 |
~820nm (PDF) and ~840nm (PDF):
Wavelength (nm) | Model | Central Wavelength (nm) | Spectrum Width (nm) | Power (mW) |
780 – 860 | OLSLD-82-MP | 830 | 20 | 2 |
800 – 860 | OLSLD-82-HP1 | 830 | 18 | 10 |
800 – 860 | OLSLD-82-HP2 | 830 | 18 | 20 |
820 – 840 | OLSLD-84-MP | 835 | 50 | 1.25 |
820 – 860 | OLSLD-84-HP1 | 840 | 50 | 7.5 |
820 – 860 | OLSLD-84-HP2 | 840 | 50 | 15 |
820 – 860 | OLSLD-84-HP3 | 840 | 50 | 25 |
Wavelength (nm) | Model | Central Wavelength (nm) | Spectrum Width (nm) | Power (mW) |
910 – 950 | OLSLD-95-MP | 935 | 70 | 1.5 |
910 – 950 | OLSLD-95-HP1 | 935 | 70 | 3.5 |
910 – 950 | OLSLD-95-HP2 | 935 | 65 | 10 |
960 – 980 | OLSLD-98-MP | 970 | 20 | 3 |
945 – 970 | OLSLD-98-HP1 | 960 | 35 | 10 |
945 – 970 | OLSLD-98-HP2 | 960 | 30 | 20 |
945 – 970 | OLSLD-98-HP3 | 960 | 30 | 30 |
Wavelength (nm) | Model | Central Wavelength (nm) | Spectrum Width (nm) | Power (mW) |
1010 – 1040 | OLSLD-02-MP | 1025 | 110 | 2 |
1010 – 1040 | OLSLD-02-HP1 | 1025 | 95 | 5 |
1025 – 1050 | OLSLD-05-MP1 | 1045 | 70 | 1.5 |
1030 – 1065 | OLSLD-05-MP2 | 1050 | 35 | 5 |
1040 – 1060 | OLSLD-05-HP1 | 1050 | 30 | 10 |
1040 – 1060 | OLSLD-05-HP2 | 1050 | 35 | 20 |
1040 – 1060 | OLSLD-05-HP3 | 1050 | 35 | 30 |
~1310nm (PDF):
Wavelength (nm) | Model | Central Wavelength (nm) | Spectrum Width (nm) | Power (mW) |
1290 – 1330 | OLSLD-13-MP | 1310 | 40 | 2 |
1290 – 1330 | OLSLD-13-HP1 | 1310 | 50 | 5 |
1290 – 1330 | OLSLD-13-HP2 | 1300 | 30 | 10 |
1290 – 1320 | OLSLD-13-HP3 | 1300 | 30 | 15 |
1290 – 1320 | OLSLD-13-HP4 | 1300 | 30 | 20 |
1290 – 1330 | OLSLD-13-HP5 | 1310 | 32 | 45 |
~1400nm (PDF):
Wavelength (nm) | Model | Central Wavelength (nm) | Spectrum Width (nm) | Power (mW) |
1380 – 1420 | OLSLD-14-HP2 | 1400 | 30 | 15 |
1415 – 1445 | OLSLD-14-HP3 | 1430 | 40 | 15 |
1460 – 1500 | OLSLD-14-HP4 | 1480 | 50 | 15 |
~1500nm (PDF):
Wavelength (nm) | Model | Central Wavelength (nm) | Spectrum Width (nm) | Power (mW) |
1530 – 1570 | OLSLD-15-MP | 1550 | 55 | 3 |
1530 – 1570 | OLSLD-15-HP1 | 1550 | 60 | 5 |
1530 – 1570 | OLSLD-15-HP2 | 1550 | 35 | 15 |
1530 – 1570 | OLSLD-15-HP3 | 1550 | 40 | 25 |
1530 – 1570 | OLSLD-15-HP4 | 1550 | 35 | 35 |
~1600nm (PDF):
Wavelength (nm) | Model | Central Wavelength (nm) | Spectrum Width (nm) | Power (mW) |
1580 – 1620 | OLSLD-16-HP1 | 1600 | 55 | 5 |
Order Code: see PDF.
Other configurations on request.
SWB Light source
Opto-Link provides Super-Wide Band light sources in E+S+C+L+U-band or O+E -band.
Applications:
- Optical Coherence Tomography (OCT)
- Fiber Optic Sensing Application
- Fiber Optic Components Characterization
* Spectrum peaked at the typical value is not guaranteed if not specially requested.
O+E band (PDF):
Parameter | Performance | |
Dual Central Wavelength | 1300+/-20 nm and 1400+/-20 nm | |
Output Power | > +7 dBm | |
Spectral Density | > -28 dBm/nm (1260 nm to 1460 nm) | |
Peak Spectral Density | -7 dBm/nm | |
Power Stability | < ± 0.015 dB (over 8 hours) | |
Spectral Density Stability | < ± 0.01 dB (over 8 hours) | |
Ripple | < 0.3 dB/nm | |
Interface | FC/APC, others are available on request | |
Fiber | SMF | |
Operating Temperature | 0 ~40 ºC | |
Storage Temperature | -20 ~60 ºC | |
Power Supply | 110/ 230 V AC, 50/60 Hz | |
Dimension | 275 x 250 x 100 mm3 |
E+S+C+L+U-band (PDF):
Parameter | Performance |
Central Wavelength | 1540 nm |
Output Power | > 8 mW (10mW, typical ) |
Spectral Density | > -20 dBm/nm (1440 nm to 1620 nm) |
> -25 dBm/nm (1420 nm to 1640 nm) | |
Peak Spectral Density | -7 dBm/nm |
Power Stability | < ± 0.02 dB (over 8 hours) |
Ripple | < 0.1 dB |
Interface | FC/APC, others are available on request |
Fiber | SMF |
Operating Temperature | 0 ~40 ºC |
Storage Temperature | -20 ~60 ºC |
Power Supply | 110/ 230 V AC, 50/60 Hz |
Dimension | 257.5 x 324 x 103 mm3 |
Order Code: see PDF.
Other configurations on request.
Variable Optical Attenuator (PDF)
Opto-Link provides VOA in various formats (manual, electrical, benchtop, PM).
Applications:
- CATV systems
- DWDM networks
- Optical add/drop multiplexing
- Optical communication system testing
- Optical device manufacturing
- Optical parameter measurement
- Telecommunication systems
- Power control and equalization in multichannel systems
Manual:
Parameter | Manual | Unit | |
Calibrated Wavelength | 1310, 1550, 1310/1550 | nm | |
Attenuation Range | 0 to 40 | dB | |
Resolution |
0-10dB
|
0.1 | dB |
10-20dB
|
dB | ||
20-40dB
|
0.3 | dB | |
Insertion Loss |
Typ
|
0.5 | dB |
Max
|
1.0 | dB | |
Return Loss |
Typ
|
50 | dB |
Polarization Dependent Loss (PDL) |
0-20dB
|
< 0.15 | dB |
20-40dB
|
< 0.3 | dB | |
Operating Temperature | 0 to +60 | ºC | |
Storage Temperature | -20 to +70 | ºC | |
Dimensions | 24 x 12 x 12 | mm³ |
Electrical:
Parameter | Electrical | Unit | |
Calibrated Wavelength | 1310, 1550, 1310/1550 | nm | |
Attenuation Range | 0 to 30 | dB | |
Resolution | 0.1 | dB | |
Insertion Loss |
Max
|
0.6 | dB |
Return Loss |
Typ
|
45 | dB |
Polarization Dependent Loss (PDL) | < 0.1 | dB | |
Operating Temperature | -15 to +70 | ºC | |
Storage Temperature | -40 to +85 | ºC | |
Dimensions | 50 x 25 x 12 | mm³ |
Benchtop:
Parameter |
Performance | Unit | |
Operating Wavelength | 1280 to 1580 | nm | |
Calibrated Wavelength | 1310, 1550, 1310/1550 | nm | |
Attenuation Range | 0 to 60 | dB | |
Attenuation Deviation Accuracy | ±0.5 | dB | |
Resolution | 0.01 (Typical), 0.02 (Max) | dB | |
Residual Attenuation | Max | 1.5 | dB |
Return Loss | Min | 45 | dB |
Switching Repeatability | ±0.1 | dB | |
Max. Allowable Input Level | 300 | mW | |
Polarization Dependent Loss | 0.05 (Typical), 0.15 (Max) | dB | |
Power Supply | 220V AC | ||
Operating Temperature | 0 to 50 | ºC | |
Storage Temperature | -10 to +60 | ºC | |
Dimensions | 210 x 206 x 80 | mm³ |
Polarization-Maintaining:
Parameter | Manual | Unit |
Center Wavelength | 1550 | nm |
Operating Wavelength Range | +/- 10 | nm |
Excess Loss | 1 | dB |
Attenuation Loss | ~35 | dB |
Min. Return Loss | >50 | dB |
Min. Extinction Ratio | 20 | dB |
Max. Optical Power | 500 | mW |
Max. Tensile Load | 5 | N |
Operating Temperature | 0 to +65 | ºC |
Storage Temperature | -40 to +85 | ºC |
Fiber Type | PM 1550 Panda Fiber | — |
Order Code: see PDF.
Other configurations on request.